PLC Automation & Integration
Control logic, HMI and upper-layer integration on the PLC platforms Taiwan's factories actually run: Beckhoff, Mitsubishi and Keyence.
Platforms We Work On
Three controller families, each programmed in its own vendor toolchain and connected over its native protocols
Beckhoff
- Series
- TwinCAT 3
- Protocols
- ADS, EtherCAT
- Tools
- TwinCAT XAE, IEC 61131-3 Structured Text
Mitsubishi
- Series
- MELSEC iQ-R / iQ-F
- Protocols
- MC Protocol, SLMP
- Tools
- GX Works3
Keyence
- Series
- KV-8000 series
- Protocols
- MC-compatible communication
- Tools
- KV STUDIO
What We Deliver
From the I/O list to the handed-over program, one team covers the controller, the operator screens and the data path upward
Control logic development
PLC programs for new lines and for retrofits of running lines, written against the customer's I/O list and sequence specification.
HMI and operator screens
Operator screens that match the control logic: alarms, recipes and manual modes, designed with the people who run the line.
Data acquisition and MES handoff
PLC data to the upper layers over Modbus, ADS or MC Protocol, so production records and traceability come from the controller itself.
Commissioning and on-site support
Commissioning and support from our service coverage in Hsinchu, Taichung, Tainan and Kaohsiung.
Where the PLC Sits
Field I/O into the controller, the controller into an edge gateway, and the gateway into the factory's MES and dashboards
Field I/O
Sensors, actuators, drives and remote I/O terminals wired to the controller over EtherCAT or hardwired signals
PLC
Runs the control logic and sequence, owns the machine state and exposes it over ADS, MC Protocol or Modbus
Edge / gateway
Polls the controller, buffers and normalizes the data and forwards it to the upper layers
MES / dashboards
Production records, traceability and live dashboards built from the controller's data
Related Offerings
Three layers of one architecture: the controller, its monitoring, and the factory host.
How We Deliver
Three steps from the I/O list to a documented program running on site
Requirements and I/O list review
Confirm the sequence, the I/O list and the interfaces to upstream and downstream equipment.
Logic development and simulation
Write and simulate the control logic and screens before the hardware is on site.
Commissioning and handover
Commission on site, train operators and hand over the documented program.
Planning a new line or a retrofit?
Tell us the controller family, the I/O count and what the upper layers need to see. We will scope the program and the integration with you.
Talk to us about PLC projects